Keskusyksiköt
| I/O-yksiköt | Teollisuusmodeemit |
Ohjelmistot | Lisälaitteet |
EtherTRAK-2
EtherTRAK
RemoteTRAK
SixTRAK
|
| |
|
| EtherTRAK-2 |
PoE-virransyötöllä
|
|
|
|
|
Kuvaus |
|
|
24 |
8 |
8 |
0 |
Combination I/O with 1 isolated input counter * |
|
|
24 |
8 |
8 |
2 |
Combination I/O with 2 analog outputs |
|
|
32 |
- |
- |
- |
32 inputs (10-30 VDC) |
|
|
16 |
- |
- |
- |
16 individually isolated channels, 10-30 VDC/VAC with counters |
|
- |
16 |
- |
- |
- |
16 individually isolated inputs,120 VAC nominal |
|
|
- |
32 |
- |
- |
High density discrete outputs |
|
|
- |
16 |
- |
- |
Individually isolated 1 Amp outputs with self-resetting fuses |
|
|
- |
- |
32 |
- |
High density 16 bit 4-20mA inputs with self-resetting fuses |
|
|
- |
- |
32 |
- |
|
|
|
- |
- |
16 |
- |
16 channels 4-20mA inputs with self-resetting fuses
|
|
|
- |
- |
- |
8 |
|
|
|
- |
- |
16 |
8 |
16 4-20mA inputs plus 8 4-20mA outputs
|
|
|
- |
- |
16
TC |
- |
Instrumentation thermocouples |
|
|
- |
- |
8
TC |
- |
Instrumentation thermocouples
|
|
|
- |
- |
16 |
- |
Isolated 4-20mA inputs |
|
|
- |
- |
10
RTD
|
- |
RTD (100 Ohm platinum), -200 to 850°C |
Huom.:
*24 maximum DI’s are listed, 8 of which can be configured as either DI or DO. The discrete outputs are protected by self-resetting fuses.
EB part number prefix (above) is for modules that include the optional PoE feature. Standard product part numbers begin with E2.
|
| |
| Tuote |
|
|
|
|
Kuvaus |
|
24 |
8 |
8 |
0 |
Double density combination I/O module |
|
16 |
- |
- |
- |
10-30 VDC, high density configuration |
| ET-16DO2-H |
- |
- |
16 |
- |
10-30 VDC, 1 Amp / channel, high density |
| ET-16AI2-H |
- |
16 |
- |
- |
4-20 mA, high speed, 14-Bit |
| ET-8INS-U |
- |
8 |
- |
- |
Instrumentation (thermocouples, mV, etc.) |
| ET-8CNT-U |
8 |
- |
- |
- |
High speed counters (quad., frequency, etc. |
ET-8DI2-8DO2-H
ET-8DI2-8AI2-H
|
8 |
- |
8 |
- |
10-30 VDC, 1 A / ulostulo |
| ET-8AI2-4AO2-H |
- |
8 |
- |
4 |
4-20 mA (14-bit) ins and 4-20 mA (16-bit) outs |
|
4 |
4 |
- |
- |
RTD (100 Ohm platinum) & 10-30 VDC input |
|
| |
|
| |
| |
| RemoteTRAK |
| Tuote |
|
|
|
|
Kuvaus |
|
8 |
- |
- |
- |
10-30VDC discrete inputs, field wiring |
|
8 |
- |
- |
- |
10-30VDC discrete inputs, universal wiring |
| RM-16DI2-H |
16 |
- |
- |
- |
10-30VDC discrete inputs, high density |
| RM-8DO2-F |
- |
- |
8 |
- |
10-30VDC discrete outputs, field wiring |
| RM-16DO2-H |
- |
- |
16 |
- |
0-30VDC discrete outputs, high density |
| RM-8AI2-F |
- |
8 |
- |
- |
4-20mA analog inputs, 16-bit resolution |
| RM-16AI2-H |
- |
16 |
- |
- |
4-20mA analog inputs, 16-bit resolution, high density |
| RM-8INS-U |
- |
8 |
- |
- |
Instrumentation inputs, (thermo
couples, Volt, 4-20mA, etc.)
|
|
- |
- |
- |
4 |
4-20mA analog outputs, 13-bit resolution |
| RM-8AO2-F |
- |
- |
- |
8 |
4-20mA analog outputs, 13-bit resolution |
| RM-4DI2-4AI2-U |
4 |
4 |
- |
- |
10-30VDC discrete inputs and 4-20mA analog inputs |
| RM-4DI2-4DO2-U |
4 |
- |
4 |
- |
10-30VDC discrete inputs and discrete outputs |
| RM-RTU-8440-F |
8 |
4 |
4 |
- |
Low cost RTU, mix of discrete ins and outs, & analog ins |
| RM-232-485-4U |
Converter for RS232 to RS485 (2 wire), connect up to 128 modules |
| RM-232-SETUP |
Field setup module (includes ST-CABLE-PF). Required for initial configuration. |
|
| SixTRAK |
| Tuote |
|
|
|
|
Kuvaus |
|
8 |
- |
- |
- |
4-10 VAC/VDC |
|
8 |
- |
- |
- |
10-32 VAC/VDC |
|
8 |
- |
- |
- |
32-60 VAC/VDC |
|
8 |
- |
- |
- |
60-140 VAC/VDC |
|
8 |
- |
- |
- |
140-265 VAC |
|
16 |
- |
- |
- |
10-32 VDC, high density |
|
16 |
8 |
8 |
- |
Combination, double density I/O |
|
12 |
8 |
8 |
4 |
Combination I/O w/4 AO |
|
32 |
- |
- |
- |
10-32 VDC, double density
|
|
8 |
- |
- |
- |
4-30VDC, high-speed counters - 50 kHz |
|
- |
- |
8 |
- |
0-60 VDC, 2A/channel |
|
- |
- |
8 |
- |
60-150 VDC, 1A/channel |
|
|
|
8 |
- |
16-140 VAC, 2A/channel |
|
- |
- |
8 |
- |
140-265 VAC, 2A/channel |
|
- |
- |
16 |
- |
10-32 VDC, 0.5 Amps per channel |
|
- |
- |
6 |
- |
Form C (SPDT), 0-140 VAC/VDC, 2A |
|
- |
8 |
- |
- |
Instrumentation - thermocouples, mV... |
|
- |
8 |
- |
- |
4-20 mA, field wiring ready |
|
- |
16 |
- |
- |
4-20 mA, high density configuration |
|
- |
8 |
- |
- |
+/- 1, 2, 5, 10 volts |
|
- |
6 |
- |
- |
RTD (100 Ohm platinum), -200 to 850°C |
|
- |
6 |
- |
- |
RTD (10 Ohm copper), -200 to 260 °C |
|
- |
- |
- |
4 |
4-20 mA (requires 10-30V loop power) |
|
- |
- |
- |
8 |
4-20 mA (requires 10-30V loop power) |
|
- |
- |
- |
8 |
0-5, 0-10, +/-5, and +/-10 volts |
|
|
|
|
|
| |
EtherTRAK-2 |

Module Health Reporting on the operational status of the I/O module itself
Hot swap for instant installation and maintenance
Self-resetting fuses protect I/O against short circuits
Fast analog inputs report time integrated, and very stable 16 bit results
Web-based I/O configuration and monitoring
Stores project documentation in a quick-access web server
Easy to view LEDs provide complete status info
OEM customizable components and labeling, web pages can include your logo and identification, part numbers, etc
I/O Concentrator can poll other Modbus or Sixnet I/O devices and report I/O status of as many as 512 discrete and 256 analog registers from 16 remote devices
Time proportioned outputs can be configured to pulse on with a duty cycle proportional to analog output register
20 year support policy – making your job easier forever!
|
EtherTRAK |

24 Discrete Inputs and/or 8 Discrete Outputs and 8 Analog Inputs in one compact module
Ethernet or RS485 Modbus compatibility
High density design saves space and cost
16 bit A/D for precision measurements
True hot swap of modules in live systems
|
RemoteTRAK |

Twisted pair wiring (standard 2-wire RS485)
Spread I/O over extended distances (up to 2 miles)
Expand Modbus I/O installations
Expand SIXNET EtherTRAK I/O, Controller, RTU
and I/O Concentrator stations
Supports Modbus ASCII & RTU
"Process Quality" I/O
True hot swap of modules in live systems
DIN rail or direct panel mounting
Rugged Lexan packaging
UL, CSA, CE, DNV and Zone 2 rated
-30 to + 70°C operating range
Easy to use configuration software
|
SixTRAK |

When local control or applications programming must run in the controller without a connection to a computer, or if supervisory computer control becomes unavailable.
When standalone datalogging is required.
When standalone peer to peer communication with other controllers is required.
As a replacement for a legacy SixTRAK programmable gateway.
|
|